Physical Vapor Deposition (PVD) is a technique that involves converting material into a vapor phase and depositing it as a thin film in a high vacuum environment, also known as vacuum coating.

Principles and Applications of Physical Vapor Deposition (PVD)

 

Physical Vapor Deposition (PVD) is a technique that involves converting material into a vapor phase and depositing it as a thin film in a high vacuum environment, also known as vacuum coating. The process generally involves two primary mechanisms: evaporation and sputtering. In evaporation, high temperatures or high-energy beams are used to vaporize the target material into atoms or molecules. In sputtering, high-energy ions from plasma strike the target material, causing atoms to be ejected and deposited onto a substrate. Since PVD is a purely physical process, unlike Chemical Vapor Deposition (CVD), it can be used to deposit films of almost any material, including metals, semiconductors, and insulators. Although the PVD process requires precise control, it ensures high-quality films with excellent precision, making it widely used in various high-tech fields.


PVD technology has broad applications in both research and industry. In the electronics and semiconductor industries, PVD is used to deposit metals for integrated circuit interconnections, magnetic storage media, and transistor films. For instance, magnetic films in hard disk drives and metal interconnections in chip manufacturing commonly use sputtering deposition. In optics, many optical coatings, such as antireflection coatings, antiglare coatings, and mirror coatings, are made using PVD (especially sputtering) to achieve precise and uniform thickness control. In addition, PVD is an essential method for fabricating new thin film materials in materials science and engineering. Researchers use PVD to deposit functional films on substrates to study their mechanical, electrical, and magnetic properties. PVD is also widely used in surface engineering (e.g., wear-resistant coatings for cutting tools and molds) and high-end decoration (e.g., durable gold coatings for watch cases), significantly enhancing surface performance and aesthetics.


Basic Steps and Importance of Sample Preparation

 

High-quality deposition requires strict sample preparation procedures. First, the substrate surface must be thoroughly cleaned and dried to avoid contamination from oils, moisture, and other pollutants that may affect the film’s adhesion and purity. For research samples, common cleaning steps include solvent cleaning and plasma cleaning to ensure a clean, impurity-free surface. If necessary, pre-sputter cleaning can be performed before coating. This involves briefly acting as the cathode in a plasma to remove surface oxides or adsorbed materials. These preparatory steps are crucial for improving the film’s adhesion.


Next, the substrate is fixed on the sample holder in the deposition chamber, and the chamber is evacuated to the required base pressure. Once the working vacuum is reached, sputtering gas (usually high-purity argon) is introduced into the chamber and maintained at the appropriate pressure. For example, the SD-900 deposition system is equipped with an efficient rotary pump that can evacuate the chamber to the working vacuum (~2 Pa) within 2 minutes, greatly reducing wait times and minimizing residual gas adsorption on the substrate surface. The faster evacuation and clean environment help minimize oxidation and contamination during the initial stages of film growth.

 

After the desired process pressure is reached, the sputtering power is activated, and plasma is generated. At this point, sputtering parameters such as gas pressure, ion current, and sputtering time must be precisely controlled. The SD-900 uses CPU-controlled timing and functionality, with intuitive and reliable parameter settings that allow for real-time adjustments of chamber pressure and ion current to achieve the best coating results. Proper process settings ensure that films grow at an optimal rate (with SD-900’s sputtering rate reaching up to 4 nm per minute), avoiding damage from excessive temperature rise and controlling grain growth and stress.

 

Each step in the sample preparation process directly influences the final quality of the thin film. For example, a clean surface ensures better film adhesion and reduces interfacial defects. Optimized vacuum and atmospheric conditions prevent oxidation, discoloration, or the formation of pores during film deposition. Uniform process parameters and sample rotation ensure film thickness uniformity over large areas. Studies show that with proper sample preparation, dense and pure films can be obtained, significantly reducing pinholes and impurity content. Additionally, when films are deposited multiple times, thickness consistency is more reliably maintained, as sputtering deposition allows precise control of film thickness through current and time, enabling reproducible film thickness targets. Therefore, combining standardized sample preparation with stable deposition systems like the SD-900 ensures that film quality, uniformity, and reproducibility meet high scientific standards.



Principles and Advantages of Dual DC Sputtering Technology

 

Direct Current (DC) Ion Sputtering is one of the most basic and early applied sputtering deposition techniques. In a typical DC sputtering system, the target is connected to the cathode, and the substrate or chamber acts as the anode. A high-voltage DC electric field is applied between the two electrodes, accelerating positive ions in the plasma to strike the surface of the cathode target. High-speed argon ions eject atoms from the target, and these sputtered atoms then travel toward the substrate and deposit as a thin film. Since this sputtering device primarily relies on the electric field between the cathode and anode to maintain discharge, it is often referred to as a "dual-electrode sputtering" system, with the core process still being the physical bombardment of the target by DC plasma.

 

DC sputtering has the advantages of simplicity and ease of use. However, due to the lack of magnetic confinement and other enhancements, its efficiency in maintaining plasma and deposition rate is relatively low. For example, traditional DC sputtering requires a certain gas pressure (>0.1 Pa) of argon to maintain discharge and cannot directly sputter insulating materials (because DC charge would accumulate on the insulating target). To address these shortcomings, technologies like RF sputtering and magnetron sputtering have been developed. Nevertheless, DC sputtering is still widely used in many research and production scenarios due to its reliability, low cost, and suitability for sputtering metal and other conductive material films.

 

Dual DC ion sputtering offers unique advantages due to the continuous ion bombardment. First, DC sputtering provides a steady ion energy input, meaning that deposited atoms still possess high energy when they reach the substrate. This helps in atomic rearrangement and dense packing during film growth. Studies have shown that DC sputtered atoms have 1 to 2 orders of magnitude higher energy than those from thermal evaporation. When high-energy atoms deposit on the substrate surface, they convert their energy into heat and promote atomic diffusion, thus enhancing the bonding between the film and substrate. Some high-speed atoms even embed into the surface of the substrate, forming a transitional diffusion layer, which further improves the film’s adhesion. Additionally, the continuous bombardment of the substrate by plasma during sputtering has an in-situ cleaning and activation effect, removing poorly adhered particles and cleaning the surface, which further increases the film’s density and adhesion. As a result, films grown by DC sputtering are often dense and firmly bonded to the substrate, achieving excellent adhesion even in thick film deposits.

 

Furthermore, thanks to the precise control of DC sputtering current, the deposition rate and final film thickness can be linearly controlled by adjusting the sputtering current. This allows for highly consistent film thickness and uniformity in repeated experiments. In contrast, some more efficient sputtering methods (e.g., magnetron sputtering) may have electrons bound away from the substrate due to the magnetic field, which results in higher deposition rates and lower substrate heating. However, in applications requiring additional ion bombardment energy to improve film density and stress control, DC sputtering is more advantageous. Real-world cases have shown that for thick films requiring high adhesion, DC sputtering provides greater ion bombardment, achieving film densities and adhesion levels that magnetron sputtering cannot reach.

 

The VPI SD-900 deposition system is based on DC sputtering technology and has been optimized for engineering implementation. The SD-900 is equipped with precise vacuum gauges and current displays, and features a micro-leak valve on the front panel that can introduce gases such as argon and nitrogen. Users can select the appropriate gas and finely adjust the flow to stabilize plasma. Additionally, its high-voltage DC power supply provides an adjustable constant current sputtering mode, allowing operators to adjust the sputtering intensity in the 0-50 mA range using the current knob, accelerating film formation while ensuring film quality. These designs enable the SD-900 to fully leverage the advantages of DC ion sputtering, improving deposition rate and reducing thermal effects on substrates, while ensuring dense and well-adhered films.

 

Core Parameters, Structural Highlights, and Typical Applications of the SD-900 Deposition System

 

The SD-900 ion sputtering deposition system, developed by VPI, integrates robust DC sputtering technology with user-friendly design. Founded in 2004, VPI (Visual Precision Instruments Co., Ltd.) has specialized in sample preparation and vacuum deposition equipment, benefiting over 3000 research institutions and enterprises worldwide. As one of VPI's flagship products, the SD-900 showcases the company's technological expertise and commitment to meeting user needs.

 

Key Technical Parameters: The SD-900 uses a DC sputtering power supply, with a standard 50 mm diameter gold target (0.1 mm thickness), and options for other targets such as silver and platinum. The vacuum system uses a high-speed rotary pump with an evacuation rate of 8 m³/h at 50 Hz, which can evacuate the chamber to the working vacuum (<2 Pa) in under 5 minutes. The system’s ultimate vacuum can reach ~2.0×10^–2 mbar (2 Pa), with a typical working pressure adjustable between 7-30 Pa. The maximum sputtering current is 50 mA (recommended ≤30 mA), with a deposition rate of up to 4 nm/min. The vacuum chamber has a diameter of 150 mm and height of 120 mm, made of scratch-resistant quartz glass, allowing easy observation of discharge and easy cleaning. The sample holder accommodates substrates of 50 mm or 70 mm diameter (custom sizes available). The overall dimensions of the system are approximately 360 mm (length) × 300 mm (width) × 380 mm (height), with a weight of about 45 kg, making it compact and easy to place. The device operates on 220 V AC power (also compatible with 110 V), with a maximum power consumption of <1.5 kW, and an internal air-cooling system to ensure stable long-term operation.

 

Structural Design Highlights: The SD-900’s design prioritizes user convenience and control. The instrument panel features prominent vacuum and current indicators, with clear and intuitive readings, showcasing a professional European instrument style. The control section uses an integrated microcomputer control system, with sputtering time and functions set digitally through knobs and buttons, and precisely executed by the CPU. For example, users can preset the sputtering duration, and the system will automatically stop sputtering and release the vacuum once the time is reached, ensuring consistent conditions in repeated experiments. The front panel has a precision gas inlet valve for introducing argon, nitrogen, and other gases, with finely adjustable flow to stabilize the plasma. Notably, the quartz glass vacuum chamber facilitates observation of discharge glow and avoids the discharge nonuniformity that may arise from metal chambers, allowing for more symmetrical and stable plasma distribution. These thoughtful design elements make the SD-900 both easy to operate and equipped with industrial-grade precision control capabilities.

 

Typical Applications: Thanks to its performance, the SD-900 serves a wide range of laboratory coating needs in materials science, electronics, physics, biology, and other fields. Below are several typical application scenarios:

  • Scanning Electron Microscope (SEM) Sample Preparation: For non-conductive or electron-beam sensitive samples, the SD-900 can rapidly sputter a thin metallic conductive film (such as Au or Pt) on the surface, usually a few nanometers thick. This film helps dissipate the charge generated by the electron beam, preventing imaging artifacts caused by sample "charging," and increasing secondary electron yield for clearer SEM images.

  • Electronic Devices and New Materials Research: In electronics and materials science experiments, small-area functional films are often prepared for performance testing. The SD-900 is ideal for depositing various pure metal films (Au, Ag, Cu, etc.) as well as metal compound films (e.g., nitrides) by introducing reactive gases during sputtering. Researchers can use it to fabricate electrodes or contact points for microelectronic devices or coat conductive layers on new energy materials to measure their conductivity.

  • Surface Modification and Small-Scale Coating Trials: The SD-900 is also used for preparing samples with specialized functional coatings or for process exploration. For example, in optics, it can sputter a metal aluminum film on glass substrates for mirror coatings or deposit titanium dioxide (using RF sputtering option) for optical multilayer testing. In wear-resistant coating research, it can sputter titanium or chromium films on small samples to test their hardness and adhesion. These trials provide valuable data for large-scale deposition processes.

 

With its high stability, ease of use, and excellent film quality, the VPI SD-900 deposition system has earned the trust of research users. It provides a flexible and reliable platform for researchers and engineers in physical vapor deposition, playing a crucial role in fundamental experiments and new materials development. Leveraging advanced equipment like the SD-900, vacuum deposition technology continues to create greater value in cutting-edge fields such as electronics, optics, and materials science.